DOI:
https://doi.org/10.20914/2310-1202-2026-1-281-290УДК:
544.6.076.32Keywords:
ion-selective electrode, conductometry, ion composition, nuclear power plant, additive technologies, express analysis, ionophoreAbstract
This study addresses the pressing issue of monitoring the ionic composition of aqueous media, which is of significant importance for the energy sector. Particular attention is paid to the development of new ionophores, environmentally friendly plasticizers, miniaturization technologies, and methods for increasing the service life of sensors. In the experimental portion of the study, a laboratory conductivity meter based on a unique cell manufactured using 3D printing was developed and tested. A comparative evaluation of electrodes made of various materials was conducted: copper, graphite and composite polymers with added graphite powder. The results showed that copper electrodes provide high measurement accuracy, while graphite electrodes exhibit overestimated readings at low concentrations due to their surface properties. This study confirms the effectiveness of the proposed approach and forms the basis for further research into the development of optimized electrode materials for ion-selective elecrodes.
References
Журавская Н.Е., Стефанович П.И., Стефанович И.С. Потенциальные риски при аварии на атомной станции // Вестник Полоцкого государственного университета. Серия F. Строительство. Прикладные науки. 2021. № 8. С. 25–32.
Бдицких А.В., Петрова А.Н., Дударев В.И. Сравнение изменений физико-химических показателей водоподготовки ТЭЦ // Вестник магистратуры. 2025. № 5-3 (164). С. 13–16.
Ефимова Д.Д. Совершенствование методов подготовки воды на ТЭС // Фундаментальные и прикладные научные исследования: инноватика в современном мире. 2021. С. 55–62.
Чириков М.Е., Гусаров А.С. К вопросу автоматизации водоподготовки и химводоочистке в энергетике // Международный журнал гуманитарных и естественных наук. 2023. № 1-2 (76). С. 118–123.
Marcinek S., Chmielewska-Śmietanko D., Pawlak M. et al. Revised application of copper ion selective electrode (Cu-ISE) in marine waters: A new meta-calibration approach // Talanta. 2021. V. 226. P. 122–170. doi: 10.1016/j.talanta.2021.122170
Belyustin A.A., Ivanovskaya I.S. The Glass Electrode and Electrode Properties of Glasses // Encyclopedia of Glass Science, Technology, History, and Culture. 2021. V. 1. P. 609–617. doi: 10.1002/9781118801017.ch2.1
Pirzada M., Altintas Z. Historical development of sensing technology // Fundamentals of Sensor Technology. Woodhead Publishing, 2023. P. 3–16. doi: 10.1016/B978-0-323-88431-0.00001-6
Mele L.J., Gajda M., Bednarczyk M. et al. Selectivity, sensitivity and detection range in ion-selective membrane-based electrochemical potentiometric sensors analyzed with poisson-boltzmann equilibrium model // IEEE Sensors Journal. 2022. V. 22. № 15. P. 15010–15021. doi: 10.1109/JSEN.2022.3188432
Tatara R., Nishio S., Tsukazaki H. et al. All-Solid-State Ion-Selective Electrode Inspired from All-Solid-State Li-Ion Batteries // Analytical Chemistry. 2025. V. 97. № 9. P. 4819–4823. doi: 10.1021/acs.analchem.4c05810
Ross J.W. Calcium-Selective Electrode with Liquid Ion Exchanger // Science. 1967. V. 156. № 3780. P. 1378–1379. doi: 10.1126/science.156.3780.1378
Morf W.E., Ammann D., Pretsch E., Simon W. Carrier antibiotics and model compounds as components of selective ion-sensitive electrodes // International Symposium on Selective Ion-Sensitive Electrodes. Butterworth-Heinemann, 1973. P. 421–439. doi: 10.1016/B978-0-408-70331-4.50029-0
Shu Y., Li C., Li Y. et al. Dibenzo-18-crown-6/Polyacrylonitrile (PAN) nanofibers for metal ions adsorption: adsorption studies for Na+ and K+ // Polymer Bulletin. 2022. V. 79. № 8. P. 6275–6288. doi: 10.1007/s00289-021-03850-3
Bondar A.V., Keresten V.M., Mikhelson K.N. Registration of small (below 1%) changes of calcium ion concentration in aqueous solutions and in serum by the constant potential coulometric method // Sensors and Actuators B: Chemical. 2022. V. 354. P. 131231. doi: 10.1016/j.snb.2021.131231
Anchaliya D., Sharma U. Selective bulk liquid membrane carrier facilitated transport of Mg2+ over Li+, Na+, K+ and Ca2+ metal ions using naphthaquinone derived redox-switchable ionophores // Main Group Metal Chemistry. 2017. V. 40. № 1-2. P. 27–33. doi: 10.1515/mgmc-2017-0023
Mizani F., Saffari S., Paiehghadr M. Trace amounts determination of barium ions by a new ion-selective electrode based on 4', 4'' (5'')-Di-Tert-Butyldibenzo-18-Crown-6 // Analytical and Bioanalytical Electrochemistry. 2023. V. 15. № 1. P. 47–56.
Zareh M.M., Abdel-Ghani N.T., Al-Sabbagh A.M. et al. DNA as a polyionic ionophore for barium sensor // BMC Chemistry. 2025. V. 19. № 1. P. 172. doi: 10.1186/s13065-025-01452-8
He W., Wu H., Chen L. et al. Green plasticizers derived from epoxidized soybean oil for poly (vinyl chloride): Continuous synthesis and evaluation in PVC films // Chemical Engineering Journal. 2020. V. 380. P. 122532. doi: 10.1016/j.cej.2019.122532
Park M., Lee D., Lee S. et al. Renewable malic acid-based plasticizers for both PVC and PLA polymers // Journal of Industrial and Engineering Chemistry. 2020. V. 88. P. 148–158. doi: 10.1016/j.jiec.2020.03.045
Hao Y., Li Y., Zhang H. et al. Synthesis and evaluation of bio-based plasticizers from 5-hydroxymethyl-2-furancarboxylic acid for poly (vinyl chloride) // Industrial & Engineering Chemistry Research. 2020. V. 59. № 40. P. 18290–18297. doi: 10.1021/acs.iecr.0c03571
Li L., Wang J., Zhu C. et al. Printing technologies for the fabrication of ion-selective electrodes // Sensing and Bio-Sensing Research. 2024. V. 44. P. 100650. doi: 10.1016/j.sbsr.2024.100650
Noviana E., McCord C.P., Clark K.M. et al. Electrochemical paper-based devices: Sensing approaches and progress toward practical applications // Lab on a Chip. 2020. V. 20. № 1. P. 9–34. doi: 10.1039/C9LC00903E
Liu T., Liang R., Qin W. Anti-fouling TiO2-Coated polymeric membrane ion-selective electrodes with photocatalytic self-cleaning properties // Analytical Chemistry. 2023. V. 95. № 16. P. 6577–6585. doi: 10.1021/acs.analchem.2c04567
Qi L., Cheng Y., Liu Y. et al. Polymeric membrane ion-selective electrodes with anti-biofouling properties by surface modification of silver nanoparticles // Sensors and Actuators B: Chemical. 2021. V. 328. P. 129014. doi: 10.1016/j.snb.2020.129014
Jiang X., Wang C., Zhang H. et al. Improving the biocompatibility of polymeric membrane potentiometric ion sensors by using a mussel-inspired polydopamine coating // Analytical Chemistry. 2019. V. 91. № 10. P. 6424–6429. doi: 10.1021/acs.analchem.9b00661
Филимонова А.А., Власова А.Ю., Камалиева Р.Ф. и др. Создание электропроводящего композита с полимерными материалами для 3D-печати на основе поверхностной модификации // Вестник ВГУИТ. 2025. Т. 87. № 3. С. 241–248. doi: 10.20914/2310-1202-2025-3-241-248