RAPID WAY TO ASSESS THE SAFETY OF PRODUCTS FROM PHENOL-FORMALDEHYDE PLASTICS

https://doi.org/10.20914/2310-1202-2014-2-135-141

Abstract

Summary. An express method for determining of volatile components in the products of phenol-formaldehyde plastics is developed by detecting them in the equilibrium gas phase using the piezosensors array. The sorption of substances-marker vapor which are the main pollutants in the air diffusing from plastic household products has been studied under identical conditions. The array of 8 piezosensors is selected providing minimal impact of water vapor on the microbalance results; maximum sensitivity to one / several classes of organic compounds; identification of phenol / formaldehyde in the mixtures. A method of evaluation the level of emissions of phenol, formaldehyde, toluene, acetone from household plastic products is developed using the piezosensors array. It has been proposed the ranking samples nonfood polymers into groups according to the danger degree based on the total content of volatile organic compounds and the presence of phenol / formaldehyde. Accuracy of the phenol determination in polymers is verified by standard spectrophotometric method with 4-aminoantipyrine, it is shown the results of both methods satisfactorily converge. The proposed method can significantly reduce the economic and time costs on analysis and expand the analytical information about the content of other volatile substances in a single measurement.

About the Authors

T. A. Kuchmenko
Voronezh state university of engineering technology
Russian Federation
Professor
Department of physical and analytical chemistry
phone (473) 255-07-62


E. V. Drozdova
Voronezh state university of engineering technology
Russian Federation
graduate
Department of physical and analytical chemistry


A. Iu. Naidysh
Voronezh state university of engineering technology
Russian Federation
student


References

1. Губернский Ю.Д., Рахманин Ю.А., Лещиков В.А. Экология жилой cреды // Вестник АМН. 2003. №3. С. 9 - 17. Gubernskii Iu.D., Rakhmanin Iu.A., Leshchikov V.A. The ecology of living environment. Vestnik AMN. [Bulletin of AMN], 2003, no. 3, pp. 9-17. (In Russ.).

2. Семенова Л.А., Мачнев Е.В. Диагноз: синдром нездорового помещения // Петербургские врачебные ведомости. 1993. №3. С. 5 - 8. Semenova L.A., Machnev E.V. Diagnosis is syndrome of illness building. Peterburgskie vrachebnye vedomosti. [The Petersburg’s doctoral statements], 1993, no. 3, pp. 5-8 (In Russ.).

3. Соколов Р.С. Химическая технология. В 2 кн. Кн 2. Металлургические процессы. Переработка химического топлива. Производство органических веществ и полимерных материалов. М.: Гуманит. изд. центр ВЛАДОС, 2000. 448 с. Sokolov R.S. Khimicheskaia tekhnologiia. Kn. 2: Metallurgicheskie protsesy. Pererabotka khimicheskogo topliva. Proizvodstvo organicheskikh veshchestv i polimernykh materialov [Chemical technology. Vol. 2: Metallurgical processes. Treatment of chemical fuel. Production of organic substances and polymer materials]. Moscow: Gumanit. izd. tsenter VLADOS, 2000, 448 p. (In Russ.).

4. ГОСТ 11235-75 Смолы фенолоформальдегидные. Методы определения свободного фенола. М.: Межгосударственный стандарт: ИПК изд-во стандартов, 1986. 11 с. GOST 11235-75 Phenol-phormaldegidnye smoly. Metody opredeleniia svobodnogo phenol. [Phenol formaldehyde resins. The methods of free phenols determination]. Moscow, Standartinform Publ., 1986. 11 p. (In Russ.).

5. ГОСТ 16704-71. Смолы фенолформальдегидные. Методы определения свободного формальдегида. М.: Межгосударственный стандарт: ИПК изд-во стандартов, 2008. 4 с. GOST 16704-71. Phenol-phormaldegidnye smoly. Metody opredeleniia svobodnogo phormaldegida. [Phenol formaldehyde resins. The methods of free formaldehyde determination]. Moscow, Standartinform Publ., 2008. 4 p. (In Russ.).

6. ГОСТ Р ИСО 16000-6-2007. Воздух замкнутых помещений. Часть 6. Определение летучих органических соединений в воздухе замкнутых помещений и испытательной камеры путем активного отбора проб на сорбент Tenax ТА с последующей термической десорбцией и газохроматографическим анализом с использованием МСД/ПИД. М.: Национальный стандарт РФ: Стандартинформ, 2007. 29 с. GOST R ISO 16000-6-2007. Vozdukh zamknutykh pomeshchenii. Chast’ 6. Opredelenie letuchikh organicheskikh soedinenii v vozdukhe zamknutykh pomeschenii i ispytatil’noi kamery putem activnogo otbora prob na sorbent Tenax TA s posleduiushchei termicheskoi desorbtsiei i gazokhromatograficheskim analizom s ispol’zovaniem MSD/PID. [Indoor air - Part 6: Determination of volatile organic compounds in indoor and test camber air by active sampling on TenaxTA sorbent, thermal desorption and gas chromatography using MS/FID (IDT)]. Moscow. Standartinform Publ., 2007. 29 p. (In Russ).

7. ГОСТ Р ИСО 16000-10-2009. Воздух замкнутых помещений. Часть 10. Определение выделения летучих органических соединений строительными и отделочными материалами Метод с использованием испытательной ячейки. М.: Национальный стандарт РФ: Стандартинформ, 2010. 20с. GOST R ISO 16000-10-2009. Vozdukh zamknutykh pomeshchenii. Chast’ 10. Opredelenie vydeleniia letuchikh organicheskikh soedinenii stroi￾tel’nymi i otdelochnymi materialami. Metod s ispol’zovaniem ispytatel’noy iacheiki. [Indoor air. Part 10. Determination of the emission of volatile organic compounds from building products and furnishing. Emission test cell method]. Moscow, Standartinform Publ., 2010. 20 p. (In Russ).

8. Кучменко Т.А. Инновационные решения в аналитическом контроле. Воронеж: ВГТА, ООО «СенТех», 2009. 252 с. Kuchmenko T.A. Innovatsionnyee resheniia v analiticheskom kontrole [Innovative solutions in analytical control]. Voronezh: VGTA, OOO «SenTekh», 2009. 252 p. (In Russ.).

9. Korenman Ya.I., Belskih N.V., Кuchmenko T.A., Rajakovic L.V. et al. The influence of water on quarts resonator effectivity and the estimation of adsorption properties of modifiers for Phenol and o-cresol determination in aqueous media // Chemical Industry. 1996. vol.7, no. 6. pp. 244-247. Korenman Ia.I., Belskih N.V., Кuchmenko T.A., Rajakovic L.V. et al. The influence of water on quarts resonator effectivity and the estimation of adsorption properties of modifiers for Phenol and ocresol determination in aqueous media.Chemical Industry. 1996. vol. 7, no. 6, pp. 244-247.

10. Кучменко Т.А., Мишина А.А. (Шуба) Особенности сорбции паров аммиака на тонких пленках кислотно-основных индикаторов // Журнал аналитической химии. 2011. Т. 66. № 8. С. 816-823. Kuchmenko T.A., Mishina A.A. Sorption specifics of volatile amines on thin films of acid-base indicators. Zhurnal analiticheskoiy khimii. [J. of anal. chem], 2011, vol. 66, no. 8, pp. 816-823 (In Russ.).

11. КучменкоТ.А., Шуба А.А., Бельских Н.В. Пример решения идентификационных задач в методе пьезокварцевого микровзвешивания смесей некоторых органических соединений Аналитика и контроль. 2012. Т. 16. № 2. С. 151 -161. Kuchmenko T.A., ShubaA.A., Bel’skikh N.V. The identification parameters of organic substances in multisensors piezoquartz microbalance. Analitika i kontrol’. [Analitics and control], 2012, vol. 16, no. 2, pp. 151-161 (In Russ.).

12. Кучменко Т.А., Коренман Я.И., Кочетова Ж.Ю. Изучение сорбции ацетона и фенола на природных покрытиях-активаторах пьезокварцевых резонаторов // Журнал аналитической химии. 2001. Т. 56. № 11. С. 1126-1131. Kuchmenko T.A., Korenman Ia.I., Kochetova Zh.Iu. Study of the sorption of acetone and phenol by natural coating-activator piezoelectric resonators. Zhurnal analiticheskoi khimii. [J. of anal. chem], 2001, vol. 56, no 11, pp. 1126- 1131 (In Russ.).

13. Кучменко Т.А., Коренман Я.И., Туникова С.А. Детектирование фенола в воздухе с применением модифицированных пьезоэлектрических кварцевых сенсоров // Журнал аналитической химии. 1997. Т.52. № 7. С. 763-766. Kuchmenko T.A., Korenman Ia.I., Tunikova S.A. Detection phenol in the air using modified piezoelectric quartz sensors. Zhurnal analiticheskoi khimii. [J. of anal. chem], 1997, vol. 52, no 7, pp 763-766 (In Russ.).